Mecha_Cylinder(Electric Cylinder):Thrust 50kgf
SCN6-050-□□□-B (NPN specifications)
SCN6-050-□□□-AB (PNP specifications)

Home(Japanese) > Table of contents > SCN6-050 >
SCN6 series photo
Trust 50kgf
Stroke:50〜300mm
Features 1
Compared to air cylinders, it is energy-saving, simple, and highly functional.
(1) The maximum number of points you can set is 16 points.
(2) Positioning operation, pitch feed operation, and pressing operation are possible.
(3) Acceleration/deceleration and movement speed can be set
Features 2
One unit can be used in a variety of ways depending on the application.
  (1) Parallel connection (I/O control)
  (2) serial connection
  (3) Air cylinder compatibility function
  (4) Self-control function
  (5) Compatible with various fieldbuses

 Specification

System model
SCN6-050-050/100/150/200/250/300-B
Stroke (mm) 50 100 150 200 250 300
Maximum thrust
(N)/(kgf):
500 / 51.0 (Typical value)
Maximum payload when power is turned on (vertical use) (kg) 30
Maximum thrust in push mode (N)/(kgf):typ 350 / 35.5
M aximum speed (mm/s) 100 (Typical value at 25℃)
Repeatable positioning accuracy (mm) ±0.01
(Short-time repeatable positioning accuracy)
 Note 1), Note 2)
Lost motion (mm) 0.3
Allowable radial load (N) 30 20 10 10 10 10
Rod diameter (mm) φ22
Rod tip screw diameter M14 Pitch1.5(SUS303)
Number of positioning points 16
Power supply DC24V±10 %
(Power supply: max. 3.0 A,
Control circuit power supply: max. 0.2 A)
Input/output signal parallel input signal Signal name DC24V DI/DO interface (connector PIO),
Target position number (4-bit binary: PC1, PC2, PC4, PC8), start (CSTR), Axis movement interlock (ILK)
input current Max 4mA/port
(Please connect with sink type output circuit)
parallel output signal Signal name DC24V DI/DO interface (connector PIO),
completed position number (4-bit binary: PC1, PC2, PC4, PC8), positioning complete (PFIN), alarm (ALM), zone signal (ZONE), home return complete (ZFIN) )
Output current Maximum 10mA/port
(open collector output)
serial signal Serial interface (connector SIO)
+5V、5G、S+、S-
Protection function Overspeed, main power overvoltage,
regenerative voltage abnormality, overload,
sensor abnormality,servo abnormality,
encoder disconnection
Environmental condition Operating temperature 0 〜 40 ℃ [Amp: 0 〜 55 ℃ ]
storage temperature -20 〜 60 ℃ [Amp: -20 〜 60 ℃ ]
Usage/storage humidity ≦ 90% RH, but no condensation
[Amp: 20〜80 % RH or less, no condensation]
protective structure IP-40 equivalent
Vibration/Shockproof 2G / 10G (2 times)
[Amplifier: 0.5G / 2G (3 times)]
Cylinder weight (kg) 1.9 2.2 2.5 2.8 3.1 3.4
Servo amplifier weight (kg) 0.4
※) Due to product improvement, some ratings, specifications, dimensions, etc. may be changed without notice
Note(1) Urethane rubber (Shore 90) for home positioning is used at both stroke ends of the electric cylinder. The aging of urethane rubber is estimated to be a maximum of 0.05 to 0.07 mm/1 to 2 years. Therefore, it is possible that the origin position may shift by up to 0.07mm due to changes over time, so processing such as data correction may be required depending on the user's usage. In addition, the home position when shipped from the factory is the backward end (motor side) home position. When using the home position on the forward end side (opposite the motor side), change it using the teaching tool.
Note(2) Positioning is done from one direction
 SCN6-050-□□□-B (NPN specifications)
External connection diagram

SCN6 series wiring diagram

 SCN6-050-□□□-B (NPN specifications)
Input/Output equivalent circuit
Input equivalent circuit NPN
Output equivalent circuit NPN
 SCN6-050-□□□-AB (PNP specifications)
External connection diagram

SCN6 series wiring diagram(PNP specification)

 SCN6-050-□□□-AB (PNP specifications)
Input/Output equivalent circuit
Input equivalent PNP specification
Output equivalent PNP specification
 Speed-thrust characteristics (at 25℃, typical value)
Speed-thrust characteristics
Dimensions
(Click on the screen to open an enlarged image as a pdf file)
One nut is included at the end of the rod
If you have any other questions, please contact us below.
Contact information